Page 84 - 《中国药房》2026年10期
P. 84

RESULTS The linear ranges of LTG, LEV and PER were 0.15-24 μg/mL (R >0.993), 0.312 5-50 μg/mL (R >0.997) and 6.25-
                                                                      2
                                                                                               2
          1  000  ng/mL (R >0.997),  respectively.  The  lower  limits  of  quantification  were  0.15  μg/mL,  0.312  5  μg/mL  and  6.25  ng/mL,
                        2
          respectively. RSDs of intraday and interday precision tests of the three drugs were no more than 9.83%, and the accuracies (relative
          errors)  were  between  -9.33%  and  13.72%(n=6  or  n=18);  the  average  extraction  recovery  rates  were  86.4%-97.9%,  and  the
          average  matrix  effects  were  86.9%-110.0% (n=6).  The  absolute  values  of  the  relative  errors  in  the  stability  tests  were  all  below
          15%. The steady-state trough concentrations of LTG, LEV and PER were (5.64±4.03)μg/mL, (10.67±8.78)μg/mL and(450.20±
          251.27)ng/mL,  respectively;  the  rates  of  achieving  target  trough  concentrations  were  71.4%,  37.5%  and  84.6%,  respectively.
          CONCLUSIONS  The established UPLC-MS/MS method is specific, rapid and suitable for the plasma concentration monitoring in
          epileptic children receiving combination therapy.
          KEYWORDS     lamotrigine; levetiracetam; perampanel; epilepsy; children; therapeutic drug monitoring; UPLC-MS/MS method


              癫痫是一类由于脑部神经元异常放电引起的反复                           谱的高灵敏度、高特异性,能区分待测物与其代谢物、结
          发作的慢性脑病,以儿童和老年人为主要发病人群。我                            构类似物,无交叉反应,且单次进样可同时检测多种待
          国癫痫患者约有 900 万例,其中儿童占 70%~80%                [1―2] 。  测物,是联合用药患者血药浓度监测的理想选择                     [9―10] 。
          临床实践显示,50%的癫痫患者首次单用一种抗癫痫药                           基于此,本研究拟建立一种同时测定癫痫患儿血浆中
          物(antiepileptic drugs,AEDs)难以控制其病情发作,故              PER、LTG 和 LEV 质量浓度的 UPLC-MS/MS 法,并将其
          中华医学会神经病学分会相关指南推荐在首种AEDs治                           应用于临床,以期为癫痫患儿的个体化精准用药提供技
                                                    [3]
          疗失败后,临床需立即考虑合理的多药联合治疗 。吡                            术支撑。
          仑帕奈(perampanel,PER)是一种高选择性、非竞争性α-                   1 材料
          氨基-3-羟基-5-甲基-4-异噁唑丙酸型谷氨酸受体拮抗                        1.1 主要仪器
          剂,可用于≥4 岁儿童及成人伴或不伴继发全面发作的                               本研究所用主要仪器包括UPLC-Xevo TQ-S型超高
                               [4]
          部分性发作癫痫的治疗 。PER 作用机制独特,在难治                          效液相色谱-串联三重四极杆质谱仪(美国 Waters 公
                                                        [5]
          性癫痫治疗中常作为添加药物与其他AEDs联合使用 。
                                                              司)、Milli-Q Advantage 型超纯水仪(美国 Millipore 公
          在针对儿童患者的治疗方案中,常见的联用方案包括
                                                              司)、AB-204-N 型电子天平(瑞士 Mettler Toledo 公司)、
          PER 联合左乙拉西坦(levetiracetam,LEV)、拉莫三嗪
                                                              995 型超低温冰箱(美国 Thermo Fisher Scientific 公司)、
         (lamotrigine,LTG)等。研究指出,12岁以下儿童对LEV
                                                              Vortex Genie 2 型涡旋振荡仪(美国 Scientific Industries
          的清除率高于成人,其血药浓度也可能异于成人,因此
                                                              公司)、Allegra 64R型高速低温离心机(美国Beckman公
          当儿童患者联合使用 LEV 时,临床应密切关注 LEV 血                       司)等。
          药浓度以保障疗效及安全性            [6―7] ;LTG因可能引发危及生
                                                              1.2 主要药品与试剂
          命的皮疹、多器官超敏反应等严重不良反应,与 PER 联
                                                                  PER对照品(批号P126771,纯度98%)、LEV对照品
          用时可竞争性结合血浆蛋白而导致血药浓度升高,加之
                                                             (批 号 B1528010,纯 度 99%)、LTG 对 照 品(批 号
          LTG 在小于 7 岁儿童体内的血药浓度与给药剂量无
                                                              H2217428,纯度 98%)均购自上海阿拉丁生化科技股份
          关 ,故临床应对儿童患者体内 LTG 的血药浓度进行实
            [8]
                                                              有限公司;吡仑帕奈-D5 (PER-D5 )对照品(内标,批号
          时监测。
                                                              C20221028,纯度 100%)购自加拿大 TRC 公司;甲酸、乙
              多药联合监测可提高临床检测效率、减少样本采集
                                                              腈、甲醇均为色谱纯,水为实验室自制超纯水。
          量,特别是对于采血困难的儿童患者,开发能同时检测
                                                              1.3 空白血浆
          多种常用 AEDs 血药浓度的方法具有一定的临床意义。
                                                                  人空白血浆由苏州市吴江区儿童医院血库提供。
          目前,血药浓度的检测方法主要有均相酶免疫法、荧光
          免疫法、化学发光免疫法、液相色谱法和超高效液相色                            2 方法与结果
          谱-串联质谱(ultra-high performance liquid chromatography-  2.1 色谱与质谱条件
          tandem mass spectrometry,UPLC-MS/MS)法等。其中,              以 ACQUITY UPLC HSS T3 C18 (2.1 mm×100 mm,
          免疫法依靠抗体与药物的特异性结合,通过荧光、化学                            1.8 μm)为色谱柱,以含0.1%甲酸的5 mmol/L乙酸铵溶
          发光信号定量,待测物易受结构类似物干扰而导致检测                            液为流动相 A(水相)、乙腈为流动相 B(有机相)进行梯
          结果呈假阳性,加之多数试剂盒每次只能用于检测1种                            度洗脱(0~1 min,5%B;1~3.5 min,5%B→95%B;3.5~
          待测物,故在联合用药患者血药浓度监测中的应用受                             4.5 min,95%B;4.5~4.6 min,95%B→5%B;4.6~5 min,
          限;液相色谱固定相种类多、流动相选择范围广,具有较                           5%B);流速为 0.3 mL/min;柱温为 40 ℃;进样量为 5
          好的选择性和重复性,但检测结果易受内源性物质干                             μL;分析时间为5 min。
          扰;UPLC-MS/MS法同时具备液相色谱的高分离度和质                            采用电喷雾离子源,以多反应监测(multiple reac‐


          · 1314 ·    China Pharmacy  2026 Vol. 37  No. 10                            中国药房  2026年第37卷第10期
   79   80   81   82   83   84   85   86   87   88   89