        摘  要   目的:评价奥卡西平刻痕片仿制药与原研药溶出行为的一致性,并比较两者的外观、半片制剂的脆碎度及分割质量损失
        以及不同企业原料药的晶型、晶体形貌。方法:采用高效液相色谱法测定含量;采用桨法(设置转速60 r/min,温度37.0 ℃)测定仿
        制药与原研药在 4 种不同溶出介质[含 0.6%十二烷基硫酸钠的盐酸溶液(pH=1.2)、含 0.6%十二烷基硫酸钠的醋酸盐缓冲溶液
       (pH=4.5)、含0.6%十二烷基硫酸钠的磷酸盐缓冲溶液(pH=6.8)、含0.6%十二烷基硫酸钠的水溶液]中的累积溶出度,采用相似
        因子法评价两者溶出曲线的相似性,并评价半片与整片制剂的批内均一性;采用脆碎度检测仪及电子天平测定半片制剂的脆碎度
        及分割质量损失;采用X射线衍射仪及扫描电子显微镜观察不同企业原料药的晶型和晶体形貌。结果:奥卡西平检测质量浓度的
        线性范围为33.42~401.09 μg/mL(r=0.999 9);定量限为0.10 μg/mL,检测限为0.04 μg/mL;精密度、稳定性、重复性、耐用性试验
        的RSD均小于2%;回收率为99.80%~101.63%(RSD为0.37%~0.91%,n=3)。仿制药A、B和原研药在4种不同溶出介质中90
        min时的平均累积溶出度分别为92%、87%、90%[含0.6%十二烷基硫酸钠的盐酸溶液(pH=1.2)];94%、94%、90%[含0.6%十二
        烷基硫酸钠的醋酸盐缓冲溶液(pH=4.5)];95%、95%、91%[含0.6%十二烷基硫酸钠的磷酸盐缓冲溶液(pH=6.8)];97%、98%、
        95%(含0.6%十二烷基硫酸钠的水溶液)。仿制药A、B和原研药在上述4种溶出介质中的相似因子分别为66、81,71、69,71、61,
        59、39。前15 min时,仿制药A、B和原研药半片与整片的溶出度差值分别为-3%~13%、-2%~24%、-3%~7%;仿制药A半
        片、整片累积溶出度的RSD分别为6%~14%、2%~9%(n=12),仿制药B为4%~10%、1%~8%(n=12),原研药为2%~7%、
        2%~8%(n=12)。原研药外观为梭形,刻痕较深;仿制药片形各异,且刻痕明显浅于原研药。仿制药A、B和原研药的脆碎度、分
        割质量损失分别为0.62%、0.67%,0.12%、0.11%,0.08%、0.05%。国产原料药呈不规则的块状和碎屑,原研药企业产原料药呈规
        则的扁平长方体和规则的条状且碎屑少;但两者的X射线衍射特征峰基本一致。结论:仿制药A在4种溶出介质中的溶出行为与
        原研药一致;仿制药B在含0.6%十二烷基硫酸钠的水溶液中的溶出行为与原研药不同;原研药掰分前后批内均一性无明显变化,
        而仿制药A、B掰分后的批内均一性较整片有所降低;仿制药的脆碎度和分割质量损失均高于原研药;两者原料药晶型相同但晶
        体形貌存有差异。
        关键词 奥卡西平;溶出行为;刻痕片;仿制药;原研药;一致性评价;高效液相色谱法

        Consistency Evaluation on the Dissolution Behavior and Related Indicators between Generic and Original
        Preparations of Oxcarbazepine Scored Tablets
                                                                                  1,2
                  1,2
                                                 1,2
                                                               1,2
                                   1,2
        LYU Beibei ,YANG Haiyuan ,CHENG Hua ,WEI Wenzhi ,ZHANG Minjuan (1. Chemistry Laboratory,
        Qinghai Institute for Drug Control, Xining 810016, China; 2. Qinghai Provincial Key Laboratory of
        Modernization of Traditional Chinese and Tibetan Medicine,Xining 810016,China)
        ABSTRACT    OBJECTIVE:To evaluate the dissolution behavior consistency between the generic drugs and original drugs of
        Oxcarbazepine scored tablets,and to compare the appearance,the friability of the split portions,loss of mass of the split portions
        as well as crystal form and morphology of raw material from different enterprises. METHODS:HPLC method was adopted. The
        paddle method(rotation speed of 60 r/min,the temperature of 37.0℃)was adopted to determine accumulative dissolution rate of
        generic and original drugs in 4 mediums [0.6% SDS hydrochloric acid solution(pH=1.2),0.6% SDS acetate buffer solution
       (pH=4.5),0.6% SDS phosphate buffer solution(pH=6.8)and 0.6% SDS water solution]. The similarity factor method was used
        to evaluate the similarity of dissolution curves as well as intra-batch uniformity of the split portions and whole tablets. The friability
        tester and electronic balance were used to determine the friability and the loss of mass of the split portions. X-ray diffractometer and
        scanning electron microscope were used to observe the crystal form and crystal morphology of the raw materials of different
                                                           enterprises. RESULTS:The linear range of oxcarbazepine was
            Δ 基金项目:国家药品抽检计划项目(No.国药监药管〔2019〕2
                                                           33.42-401.09 μg/mL(r=0.999 9);LOQ was 0.10 μg/mL,and
        号);青海省科技计划项目(No.2017-ZJ-Y40)
                                                           LOD was 0.04 μg/mL;RSDs of precision,stability,reprodu-
           *工程师,硕士。研究方向:药品质量分析、药品质量标准。电
        话:0971-8247794。E-mail:598491606@qq.com             cibility and durability tests were lower than 2.0%;the reco-
           # 通信作者:主任药师。研究方向:药品质量分析、药品质量标                   veries were 99.80% -101.63% (RSD=0.37% -0.91% ,n=3).
        准。电话:0971-8247794。E-mail:1415328549@qq.com         The average cumulative dissolution rate of generic drug A,


        中国药房    2020年第31卷第12期                                            China Pharmacy 2020 Vol. 31 No. 12  ·1463  ·